Underfloor Heating

Underfloor Heating Manifold Installation

A correctly installed underfloor heating (UFH) manifold is what makes a wet UFH system run smoothly. It distributes warm water to each pipe circuit, controls flow rates, and helps deliver even room temperatures at low operating temperatures. This service covers the supply and fitting of the manifold assembly, pump and blending valve where required, plus proper testing and commissioning so the system performs as it should.

More information

What manifold installation includes

A UFH manifold is not just a set of pipes. It is the control point for comfort, efficiency, and reliability across every heating loop. Installation typically includes:

  • Manifold selection and layout to match your number of zones and circuits.
  • Mounting the manifold in a suitable location with access for future servicing.
  • Connecting primary flow and return pipework from the heat source.
  • Fitting a pump set and blending valve (where needed) to achieve safe UFH temperatures.
  • Connecting UFH pipe circuits, with clear labelling for each loop.
  • Pressure testing and leak checks before the system is put into use.
  • Filling, flushing and commissioning to remove air and support stable circulation.
  • Flow setting and initial balancing for even heat distribution.
  • Handover advice on basic operation and what to watch for.

When this service is a good fit

Manifold installation is ideal if you are:

  • Installing wet underfloor heating in a new build, extension, or renovation.
  • Replacing a faulty, leaking, or poorly performing manifold.
  • Adding zones or circuits and need a larger manifold or better control.
  • Switching heat sources (for example, upgrading to lower temperature heating) and need correct blending and pumping.
  • Managing a rental or small commercial space where dependable, consistent heating matters.

How the installation is delivered

Work usually follows a clear sequence:

  1. Confirm system requirements: number of loops, heat output, control approach and pipework routes.
  2. Fit and pipe in the manifold: secure mounting, isolation valves, and primary connections.
  3. Install pump and blending controls where required to protect the floor system from excessive temperatures.
  4. Connect, test and commission: pressure test, fill, purge air, and verify circulation.
  5. Balance the circuits: set flow rates and check for even heat delivery across zones.

The exact timing depends on site readiness and whether the manifold is part of a wider UFH install, but you will be kept informed on what is needed before and after the visit.

After installation: performance and peace of mind

Commissioning and balancing make a noticeable difference to comfort and running costs. After installation, you will have a system that is easier to control, simpler to service, and less likely to suffer from cold spots, noisy circulation, or uneven room temperatures. If issues show up later, the manifold provides a clear point for diagnostics and adjustment.

Frequently Asked Questions

Do I need a pump and blending valve with my underfloor heating manifold.
Many wet UFH systems need a blending valve to reduce flow temperature and a pump to circulate water through the floor loops. Whether you need them depends on your heat source and system design. This is checked before installation so the setup matches your system.
Where should the manifold be located.
It should be accessible for balancing and future servicing, and positioned to keep pipe runs practical. Common locations include a utility area, airing cupboard, or a manifold cabinet within a wall. The final position is agreed based on access, pipe routes, and controls.
Can you replace an existing manifold without changing the whole underfloor heating system.
Yes, a manifold can often be replaced while keeping the existing floor pipe circuits. The condition of the loops, valves, and controls needs to be checked first. The replacement is then tested and rebalanced to restore even performance.
Will manifold installation fix cold spots in rooms.
Cold spots are often caused by poor balancing, trapped air, or restricted flow in one or more circuits. Installing or upgrading the manifold can help, but the system still needs correct commissioning and flow setting. If another fault is present, it will be identified during testing.
How do I know the system is properly commissioned.
A commissioned system will hold pressure, circulate cleanly without excessive air, and have measured flow rates set across each loop. You should also see more consistent room temperatures and smoother control response. You will be advised on the initial settings and what adjustments, if any, may be needed after the first heating cycles.

Related Services

Complete your experience with these services

  • Underfloor Heating Zone Control Installation
    View
  • Underfloor Heating System Upgrade
    View
  • Underfloor Heating Repair
    View
  • Underfloor Heating Pump Replacement
    View
Show more services
  • Underfloor Heating Maintenance
    View
  • Underfloor Heating Leak Investigation
    View
  • Underfloor Heating Integration with Heat Pump
    View
  • Underfloor Heating Installation (Wet System)
    View
  • Underfloor Heating Fault Diagnosis
    View
  • Underfloor Heating Commissioning
    View
  • Underfloor Heating Actuator Replacement
    View